Installing your Wired Wall Mount:

Hardware included:

Hardwired_Kit_hardware_1.PNG

Tools needed:

Hardwired_Kit_tools.PNG

Shut off power at the breaker.

Hardwired_Kit_1.PNG

Note: If your power system is classified as OVC Ill, please check the building "Distribution Panel", Ex switch panel has an installed Surge Protectors. Ensure that the surge protector is a UL 1449 certified Surge Protector to reduce Main Transient Voltage to Overvoltage Category II (2500 V pk or lower) before connecting to all AC Inputs. If the there is no Surge Protector, do not install the Hardwired Kit without one.

Before you begin installing your Hardwired Kit, make sure that you're following safety code standards.

WARNING: Electrical shock hazard. Disconnect power to installation area at your circuit breaker or fuse box before beginning installation. Always use caution when handling electrical wiring. Installation by a qualified electrician may be required in your area. Refer to your local laws and building codes before performing electrical work; permits plus professional installation may be required by law. Your Hardwired Kit must be installed on a 4" round UL listed weatherproof electrical box when installed outdoors.

Junction boxes

For installing out-of-wall, 4-inch metal and plastic junction boxes.

Requires a minimum 14AWG or higher 3-core cable.

1. For metal: Connect the green earth wires with junction box earth screw. (Home protective earthing and wired mount bonding conductor wires) See connection diagram. Then connect the white (L) and black (N) wires with wire nuts.

Hardwired_Kit_metal.PNG

WARNING: If you can't easily identify the wires coming out of your junction box, or have difficulty with or are uncomfortable connecting them, consult a licensed electrician.

For plastic: Connect the green earth wires with a wire nut. (Home protective earthing and wired mount bonding conductor wires) See connection diagram. Then, connect the white (L) and black (N) wires with wire nuts.

Hardwired_Kit_plastic.PNG

WARNING: If you can't easily identify the wires coming out of your junction box, or have difficulty with or are uncomfortable connecting them, consult a licensed electrician.

Optional: Temporarily install a machine screw to hold the S-hook for help connecting the wires. Remove the temporary screw after wires are connected.

Note: If you ever need to remove for metal and plastic:

Remove the white (L) and black (N) wires. Then, remove the wired mount bonding conductor wire and the home protective earthing conductor wire.

2. For metal and plastic: Gently put the wires in the junction box and secure the wired mount to the adapter plate with 2 machine screws with o-rings.

Hardwired_Kit_2_1.PNG

3. For metal: Then, tighten the screws into the wired mount until the foam backing fully seals the junction box to prevent water from entering.

Hardwired_Kit_3_2.PNG

For plastic: Take 4 o-rings off the machine screws and apply them to 4 tapping screws. Then, tighten the screws into the wired mount until the foam backing fully seals the junction box to prevent water from entering.

Hardwired_Kit_3_1.PNG

For in-wall and out-of-wall junction boxes:

4. Apply a weatherproof silicone caulk or sealant around the outside where the wired mount and junction box or wall meet to prevent water from entering the junction box.

Hardwired_Kit_4_1.PNG

5. Apply cosmetic screw plugs.

Hardwired_Kit_5_1.PNG

For installing in-wall, 3.5-inch plastic junction box and switch box.

Requires a minimum 14AWG or higher 3-core cable.

1. For junction and switch box: Connect the green earth wires with a wire nut. Then, connect the white (L) and black (N) wires with wire nuts.

WARNING: If you can't easily identify the wires coming out of your junction box, or have difficulty with or are uncomfortable connecting them, consult a licensed electrician.

Hardwired_Kit_1_2.PNG

2. For junction and switch box: Connect the white (L), black (N), and green  (PG) wires with wire nuts.

Optional: Temporarily install a machine screw to hold the S-hook for help connecting the wires. Remove the temporary screw after wires are connected.

Hardwired_Kit_2_2.PNG

Note: If ever needed to remove for metal and plastic:

Remove the white (L) and black (N) wires. Then, remove the wired mount bonding conductor wire and the home protective earthing conductor wire.

3. For junction and switch box: Stuff the wires gently into the junction box and screw the wired mount to the adapter plate with 4 machine screws with o-rings.

Hardwired_Kit_3_3.PNG

4. For junction and switch box: Then, tighten the screws into the wired mount until the foam backing fully seals the junction box to prevent water from entering. (1. 37-1.47N/m of torque force)

Hardwired_Kit_4_2.PNG

For in-wall and out-of-wall junction boxes:

5. Apply a weatherproof silicone caulk or sealant around the outside where the wired mount and junction box or wall meet to prevent water from entering the junction box.

Hardwired_Kit_10.PNG

6. Apply cosmetic screw plugs.

Hardwired_Kit_6_3.PNG

For Spotlight Cam Pro or Plus

1. Remove weather cover.

Spotlight_Cam_1.PNG

2. Remove the battery cover.

Twist the cover counter-clockwise to remove. Slide the camera onto the wired mount's swivel arm. Then, re-attach the battery cover to lock the swivel arm in place.

Spotlight_Cam_2.PNG

3. Connect USB-C cable.

Plug the USB-C cable in to your camera's USB-C port.

Spotlight_Cam_3.PNG

4. Attach weather cover.

Snap into place to cover exposed cables.

Spotlight_Cam_4.PNG

5. Adjust camera angle.

Tighten the ball joint screw to secure the camera in place.

Spotlight_Cam_5.PNG